{"product_id":"glycol-pump-base-pump-for-split-remote-cooler-units","title":"Glycol pump | Base pump for split remote cooler units","description":"\u003ch2 data-section-id=\"q9rwmj\" data-start=\"60\" data-end=\"116\" class=\"PDq2pG_selectionAnchorContainer\"\u003eMMP-17 STAGE 3 Modular Glycol Circulation Pump | 230V\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"118\" data-end=\"481\"\u003eThe \u003cstrong data-start=\"122\" data-end=\"152\"\u003eMMP-17 STAGE 3 Glycol Pump\u003c\/strong\u003e is a high-performance magnetic drive circulation pump designed specifically for \u003cstrong data-start=\"233\" data-end=\"262\"\u003esplit remote beer coolers\u003c\/strong\u003e and long-distance glycol recirculation systems. Built with a robust modular design, this 230V pump delivers reliable coolant circulation to maintain consistent product temperatures across remote dispense installations.\u003c\/p\u003e\n\u003cp data-start=\"483\" data-end=\"828\"\u003eFeaturing a \u003cstrong data-start=\"495\" data-end=\"522\"\u003e150W single-phase motor\u003c\/strong\u003e and capable of producing up to \u003cstrong data-start=\"554\" data-end=\"584\"\u003e17 metres of head pressure\u003c\/strong\u003e with a maximum flow rate of \u003cstrong data-start=\"613\" data-end=\"639\"\u003e18.5 litres per minute\u003c\/strong\u003e, the MMP-17 is ideal for commercial pubs, bars, breweries, restaurants and beverage dispense systems where dependable glycol circulation is essential.\u003c\/p\u003e\n\u003cp data-start=\"830\" data-end=\"1212\"\u003eUnlike traditional pumps, the MMP series uses a \u003cstrong data-start=\"878\" data-end=\"921\"\u003emagnetically coupled centrifugal design\u003c\/strong\u003e, eliminating shaft seals for improved reliability and reduced maintenance. Its innovative modular construction also allows the motor, hydraulic section and turbine assembly to be replaced independently, significantly reducing downtime and repair costs.\u003c\/p\u003e\n\u003cp data-start=\"1214\" data-end=\"1505\"\u003eThe aluminium motor housing provides excellent heat dissipation, while the pump features \u003cstrong data-start=\"1303\" data-end=\"1322\"\u003eIP44 protection\u003c\/strong\u003e, built-in thermal overload protection and corrosion-resistant stainless steel components for long service life in demanding cellar environments.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1507\" data-end=\"1522\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1524\" data-end=\"2122\"\u003e\n\u003cli data-section-id=\"970wer\" data-start=\"1524\" data-end=\"1582\"\u003eDesigned for split remote beer cooler glycol circulation\u003c\/li\u003e\n\u003cli data-section-id=\"1cqaj8s\" data-start=\"1583\" data-end=\"1656\"\u003eMagnetically coupled centrifugal pump for reliable, leak-free operation\u003c\/li\u003e\n\u003cli data-section-id=\"npii04\" data-start=\"1657\" data-end=\"1713\"\u003eModular design allows individual component replacement\u003c\/li\u003e\n\u003cli data-section-id=\"81g3y4\" data-start=\"1714\" data-end=\"1739\"\u003e230V single-phase motor\u003c\/li\u003e\n\u003cli data-section-id=\"1j3fgh0\" data-start=\"1740\" data-end=\"1778\"\u003eBuilt-in thermal overload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1e4hk2y\" data-start=\"1779\" data-end=\"1813\"\u003eExtruded aluminium motor housing\u003c\/li\u003e\n\u003cli data-section-id=\"155po2w\" data-start=\"1814\" data-end=\"1869\"\u003eStainless steel shaft and corrosion-resistant fixings\u003c\/li\u003e\n\u003cli data-section-id=\"1bkgsd5\" data-start=\"1870\" data-end=\"1913\"\u003eAir-cooled motor for continuous operation\u003c\/li\u003e\n\u003cli data-section-id=\"za098w\" data-start=\"1914\" data-end=\"1973\"\u003ePreset swivel outlet with John Guest push-fit connections\u003c\/li\u003e\n\u003cli data-section-id=\"z1o7w1\" data-start=\"1974\" data-end=\"2017\"\u003eSuitable for continuous 24-hour operation\u003c\/li\u003e\n\u003cli data-section-id=\"4z41tw\" data-start=\"2018\" data-end=\"2122\"\u003eEasy installation and servicing with modular fixing plate system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"2124\" data-end=\"2151\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2153\" data-end=\"2509\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2153\" data-end=\"2178\"\u003e\n\u003ctr data-start=\"2153\" data-end=\"2178\"\u003e\n\u003cth data-start=\"2153\" data-end=\"2169\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2169\" data-end=\"2178\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2205\" data-end=\"2509\"\u003e\n\u003ctr data-start=\"2205\" data-end=\"2231\"\u003e\n\u003ctd data-start=\"2205\" data-end=\"2213\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2213\" data-end=\"2231\" data-col-size=\"sm\"\u003eMMP-17 STAGE 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2232\" data-end=\"2250\"\u003e\n\u003ctd data-start=\"2232\" data-end=\"2242\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2242\" data-end=\"2250\"\u003e230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2251\" data-end=\"2271\"\u003e\n\u003ctd data-start=\"2251\" data-end=\"2263\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-start=\"2263\" data-end=\"2271\" data-col-size=\"sm\"\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2272\" data-end=\"2296\"\u003e\n\u003ctd data-start=\"2272\" data-end=\"2280\" data-col-size=\"sm\"\u003ePhase\u003c\/td\u003e\n\u003ctd data-start=\"2280\" data-end=\"2296\" data-col-size=\"sm\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2297\" data-end=\"2325\"\u003e\n\u003ctd data-start=\"2297\" data-end=\"2317\" data-col-size=\"sm\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-start=\"2317\" data-end=\"2325\" data-col-size=\"sm\"\u003e150W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2326\" data-end=\"2344\"\u003e\n\u003ctd data-start=\"2326\" data-end=\"2336\" data-col-size=\"sm\"\u003eCurrent\u003c\/td\u003e\n\u003ctd data-start=\"2336\" data-end=\"2344\" data-col-size=\"sm\"\u003e0.7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2345\" data-end=\"2366\"\u003e\n\u003ctd data-start=\"2345\" data-end=\"2353\" data-col-size=\"sm\"\u003eSpeed\u003c\/td\u003e\n\u003ctd data-start=\"2353\" data-end=\"2366\" data-col-size=\"sm\"\u003e2,800 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2367\" data-end=\"2395\"\u003e\n\u003ctd data-start=\"2367\" data-end=\"2382\" data-col-size=\"sm\"\u003eMaximum Head\u003c\/td\u003e\n\u003ctd data-start=\"2382\" data-end=\"2395\" data-col-size=\"sm\"\u003e17 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2396\" data-end=\"2430\"\u003e\n\u003ctd data-start=\"2396\" data-end=\"2416\" data-col-size=\"sm\"\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2416\" data-end=\"2430\"\u003e18.5 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2431\" data-end=\"2449\"\u003e\n\u003ctd data-start=\"2431\" data-end=\"2440\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2440\" data-end=\"2449\" data-col-size=\"sm\"\u003e2.8kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2450\" data-end=\"2478\"\u003e\n\u003ctd data-start=\"2450\" data-end=\"2470\" data-col-size=\"sm\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2470\" data-end=\"2478\"\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2479\" data-end=\"2509\"\u003e\n\u003ctd data-start=\"2479\" data-end=\"2498\" data-col-size=\"sm\"\u003eInsulation Class\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2498\" data-end=\"2509\"\u003eClass F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"2511\" data-end=\"2617\"\u003e\u003cem data-start=\"2511\" data-end=\"2579\"\u003ePerformance figures are based on testing with clean water at 20°C.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1vdrhtn\" data-start=\"2619\" data-end=\"2631\"\u003eIdeal For\u003c\/h2\u003e\n\u003cul data-start=\"2633\" data-end=\"2837\"\u003e\n\u003cli data-section-id=\"1q8igv9\" data-start=\"2633\" data-end=\"2660\"\u003eSplit remote beer coolers\u003c\/li\u003e\n\u003cli data-section-id=\"1o7uko4\" data-start=\"2661\" data-end=\"2691\"\u003eGlycol recirculation systems\u003c\/li\u003e\n\u003cli data-section-id=\"pm21pj\" data-start=\"2692\" data-end=\"2729\"\u003eLong python beer line installations\u003c\/li\u003e\n\u003cli data-section-id=\"95asy1\" data-start=\"2730\" data-end=\"2756\"\u003eCommercial bars and pubs\u003c\/li\u003e\n\u003cli data-section-id=\"dn8nxe\" data-start=\"2757\" data-end=\"2768\"\u003eBreweries\u003c\/li\u003e\n\u003cli data-section-id=\"jgudau\" data-start=\"2769\" data-end=\"2782\"\u003eRestaurants\u003c\/li\u003e\n\u003cli data-section-id=\"1dp05na\" data-start=\"2783\" data-end=\"2809\"\u003eMobile bar installations\u003c\/li\u003e\n\u003cli data-section-id=\"1nhhnns\" data-start=\"2810\" data-end=\"2837\"\u003eBeverage dispense systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v5737w\" data-start=\"2839\" data-end=\"2864\"\u003eImportant Information\u003c\/h3\u003e\n\u003cul data-start=\"2866\" data-end=\"3100\"\u003e\n\u003cli data-section-id=\"1l521nu\" data-start=\"2866\" data-end=\"2888\"\u003e\u003cstrong data-start=\"2868\" data-end=\"2888\"\u003eNot self-priming\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"u4aam4\" data-start=\"2889\" data-end=\"2916\"\u003e\u003cstrong data-start=\"2891\" data-end=\"2916\"\u003eMust never be run dry\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1c2pulu\" data-start=\"2917\" data-end=\"2995\"\u003eDesigned for continuous operation using clean glycol\/water cooling circuits.\u003c\/li\u003e\n\u003cli data-section-id=\"o3vv8h\" data-start=\"2996\" data-end=\"3100\"\u003eSuitable for use in professional beverage dispense applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3102\" data-end=\"3366\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThis \u003cstrong data-start=\"3107\" data-end=\"3137\"\u003eMMP-17 Stage 3 Glycol Pump\u003c\/strong\u003e is the ideal replacement or upgrade for commercial remote cooling systems, offering excellent reliability, straightforward maintenance and consistent glycol circulation to keep draught beer dispensing at the correct temperature.\u003c\/p\u003e","brand":"Saber","offers":[{"title":"Default Title","offer_id":54358847127885,"sku":"MMP-17 STAGE 3","price":138.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0795\/3770\/1197\/files\/glycolpumpforremotebeercooler.jpg?v=1787521764","url":"https:\/\/drin-kit.com\/pt\/products\/glycol-pump-base-pump-for-split-remote-cooler-units","provider":"Drin-Kit","version":"1.0","type":"link"}